Product Use

SMTD Wireless Remote Differential Pressure Gauge - Volume Modification Operation Guide

SMTD differential pressure gauge volume adjustment operation: Place the sensing pen at the 9 o'clock position, after P0 is displayed, move it away, then place the sensing pen again at the 9 o'clock position, after P10 is displayed, move it away, keep the sensing pen at the 3 o'clock position to enter the P10 menu, the current display shows 20 cubic units, which needs to be changed to 31 cubic units. Place the sensing pen at the 9 o'clock position for the swap operation, after multiple touches to swap, change 0 to 1, then place the sensing pen at the 9 o'clock position to swap, place it at the 3 o'clock position to change 2 to 3, finally keep the sensing pen at the 9 o'clock position to exit, wait for the 10-second countdown to finish, the volume change is successful.
345 views 0 helpful

SMTD Wireless Remote Differential Pressure Gauge - Guide for Changing Units

SMTD differential pressure gauge unit change procedure: Place the sensing pen continuously at the 9 o'clock position, remove it after P0 is displayed. Place the sensing pen again at the 9 o'clock position, remove it after P5 is displayed. Keep the sensing pen at the 3 o'clock position to enter the P5 menu, use the sensing pen at the 3 o'clock position to switch the unit to kilograms, then place the sensing pen continuously at the 9 o'clock position and wait for the 10-second countdown to complete. The unit change is successful.
300 views 0 helpful

MTU Series Vehicle-mounted Level Transmitter - Upgrade Operation Guide

Deleetech MTU series vehicle-mounted liquid level transmitter upgrade procedure: First, open the after-sales APP software (e-CAL) and register an account. After registration, click login. After logging in, use the read function to confirm that the instrument is powered normally. Place the phone on the instrument when clicking read; if numbers can be read, it indicates that the instrument is powered normally. Then move the phone away. Select the upgrade function and find the required software version number for the upgrade. Taking FW1211 as an example, click "1211", then place the phone on the instrument again, click "1211" once more, and click OK when the prompt appears. Keep the phone close to the instrument until the data packet is completely written. After writing is complete, a configuration success message will appear. After successfully reading, the version number FW1211 will be displayed, indicating the instrument has been successfully upgraded.
514 views 4 helpful

Locator signal trigger operation guide

Deleetech locator signal trigger operation: Press and hold the trigger button with your thumb for about 5 seconds, then release it to complete the trigger operation.
369 views 1 helpful

DWT9851 Radar Level Meter - Instruction Guide for Viewing Instrument ID

DWT9851 radar level meter instrument ID operation guide: First, double-click the triangle button on the right to unlock. After unlocking, place both hands on the left and right buttons respectively and press and hold. Release when the screen displays F0, then press and hold the right button to enter. The displayed number at this time is 260520. Press and hold the left button to exit; then press and hold the left button until the screen displays F1, release, and press and hold the right button to enter F1. The displayed serial number is 21. This is the entire instrument ID: 2605200021. Then press and hold the left button to exit, completing the instrument ID viewing.
353 views 0 helpful

MT Capacitive Level Meter - Volume Modification Operating Guide

Deleetech MT Capacitive Liquid Level Meter Volume Adjustment Operation Guide: Place the sensing pen at the 9 o'clock position and then move it away. Place the sensing pen at the 9 o'clock position again, and after P10 is displayed, move it away. Place the sensing pen at the 3 o'clock position to enter the volume adjustment interface, and modify the values by placing the sensing pen at the 3 o'clock position. If repositioning is needed, lightly touch with the sensing pen at the 9 o'clock position and move it away, then place it at the 3 o'clock position to adjust to the desired value. After completion, keep the sensing pen at the 9 o'clock position until P10 is displayed, move it away, and wait for the countdown to exit. The volume adjustment is then successful.
438 views 0 helpful

MT Capacitive Level Meter - Instructions for Modifying Units

Deleetech MT capacitive level meter unit modification operation guide: Place the induction pen at the 9 o'clock position, and remove it after P0 is displayed; place the induction pen at the 9 o'clock position again, and remove it after P5 is displayed. Place the induction pen at the 3 o'clock position to enter the menu. To set the unit to %, for example, place the induction pen at the 3 o'clock position again and remove it after the target unit is displayed. Then place the induction pen at the 9 o'clock position, wait for 10 seconds to exit automatically, and the unit modification is complete.
487 views 0 helpful

MT Capacitive Level Meter - Operating Guide Video for Changing Medium

Operation to change the medium of the Deleetech MT capacitive level meter: Place the induction pen at the 9 o'clock position to change CO₂ to N₂ as an example, then remove the induction pen. Place the induction pen at the 3 o'clock position to enter the P0 medium modification menu and then remove it. Keep the induction pen at the 3 o'clock position, and the medium will automatically switch. Once the display shows the target medium as nitrogen, remove the induction pen. Finally, place the induction pen at the 9 o'clock position to exit. The main interface will display the corresponding medium, thus completing the medium change.
388 views 0 helpful

MT Capacitive Level Meter - Full Point Calibration Operation Video Guide

Deleetech MT capacitive liquid level meter full-scale calibration guide: Place the sensing pen at the 9 o'clock position and then remove it, repeat once at the 9 o'clock position; next, place the sensing pen at the 3 o'clock position and remove it, repeat once at the 3 o'clock position. Wait until the numbers flash to indicate successful calibration. Finally, place the sensing pen at the 9 o'clock position to exit the menu. The screen will display 100%, indicating the full-scale calibration is complete.
406 views 1 helpful

MT Capacitive Level Meter - Zero Point Calibration Operation Video Guide

Deleetech MT capacitive level meter zero point calibration operation guide: Place the induction pen at the 9 o'clock position and remove it when P0 is displayed; place the induction pen at the 9 o'clock position again and remove it when P1 is displayed. Place the induction pen at the 3 o'clock position to enter the P1 menu, place it at the 3 o'clock position again, and wait for the numbers to flash, indicating the zero point calibration is successful. Then place the induction pen at the 9 o'clock position, remove it when P1 is displayed, wait 10 seconds for automatic exit, and the zero point calibration is complete.
423 views 0 helpful
Page 3 of 5, 42 items total