Product Use

Square Instrument-DST9851 Differential Pressure Composite Transmitter-Volume Modification Operation Guide

DST9851 differential pressure compound transmitter square meter volume modification operation: Double-click the right button to unlock the menu, long-press the left button to display P0 and then release, continue to long-press the left button until P10 is displayed and then release, long-press the right button to enter the P10 volume modification menu. The current volume is 2.0000 and needs to be changed to 1.0000 (10 cubic units). Press the left button to shift, release when one segment of the progress bar in the upper right corner is displayed. During the 'tens, hundreds, thousands' position swap, when the digit '2' in the ten-thousands place flashes, long-press the right button to change the '2' to '1'. After modification, long-press the left button to exit the volume modification menu, display P10 and release, wait for the 10-second countdown to finish. Volume modification is complete.
229 views 0 helpful

MTM-A Quality Type Level Meter - Zero Point Calibration Operation Guide

MTM-A Quality Type Level Meter Zero Calibration Operation Guide: First, place the sensing pen at the 11 o'clock position, remove it after P0 is displayed; place the sensing pen at the 11 o'clock position again, remove it after P1 is displayed; then place the sensing pen at the 5 o'clock position, enter the P1 zero setting menu, place the sensing pen at the 5 o'clock position again, wait until the value in the top right corner matches the middle value to complete the zero setting; finally, place the sensing pen at the 11 o'clock position to exit the zero setting interface, wait for the 10-second countdown to finish, zero calibration is complete.
239 views 0 helpful

MTM-A Quality Type Level Gauge - Full Point Calibration Operation Guide

MTM-A quality type level meter full-scale calibration operation: First, place the sensing pen at the 11 o'clock position, remove it after P0 is displayed, then place the sensing pen at the 11 o'clock position again, remove it after P2 is displayed, then place the sensing pen at the 5 o'clock position to enter the P2 full-scale calibration interface, remove the pen after entering the menu, then place the sensing pen at the 5 o'clock position again for full-scale calibration. When the middle value matches the top right value, the full-scale calibration is successful. Place the sensing pen at the 11 o'clock position to exit the menu, and after the 10-second countdown ends, 100% will be displayed, completing the full-scale calibration.
228 views 0 helpful

MTM-A Quality Type Level Meter - Unit Change Operation Guide

MTM-A quality type level meter unit change operation: First, place the sensing pen at the 11 o'clock position continuously, remove it after P0 is displayed, place the sensing pen at the 11 o'clock position again, remove it after P5 is displayed, place the sensing pen continuously at the 5 o'clock position to enter the P5 menu to change the unit interface, the current display unit is litres, change it to percentage, place the sensing pen continuously at the 5 o'clock position, remove it after the screen displays the percentage, place the sensing pen at the 11 o'clock position to exit the unit change interface, wait for the 10-second countdown to end, and the unit change is complete.
251 views 0 helpful

MTM-A Quality Type Level Meter - Operation Guide for Changing Medium

MTM-A quality type level meter medium change operation: Place the sensing pen at the 11 o'clock position, remove it after P0 is displayed, place the sensing pen at the 5 o'clock position, enter the P0 menu and then remove it, the current displayed medium is liquid nitrogen, place the sensing pen at the 5 o'clock position for the medium change operation, change the medium to carbon dioxide, remove the sensing pen after carbon dioxide is displayed, place the sensing pen at the 11 o'clock position to exit the interface, wait for the 10-second countdown to finish, the medium change operation is complete.
235 views 0 helpful

MTM-A Quality Type Level Meter - Volume Modification Operation Guide

MTM-A quality-type liquid level meter volume adjustment operation: Place the sensing pen continuously at the 11 o'clock position, and remove it when P0 is displayed. Then place the sensing pen at the 11 o'clock position again and remove it when P10 is displayed. P10 is the volume modification menu. Place the sensing pen continuously at the 5 o'clock position to enter the P10 volume replacement interface. The current volume displayed is 850 litres. Place the sensing pen at the 11 o'clock position, move it one step on the progress bar and remove it. At this point, the units digit “0” flashes. You need to change “850” to “900”. The units digit 0 does not need to be changed. Place the sensing pen at the 11 o'clock position to modify the tens digit. When the number flashes, remove the pen. Place the sensing pen continuously at the 5 o'clock position, change the 5 to 0, and remove it. Then place the sensing pen at the 11 o'clock position, and when the number flashes, modify the hundreds digit. Place the sensing pen at the 5 o'clock position, change the “8” to “9”, and remove it. Finally, place the sensing pen continuously at the 11 o'clock position to exit the menu. Wait for the 10-second countdown to finish, and the volume modification is successful.
219 views 0 helpful

SMTD Wireless Remote Differential Pressure Gauge - Trigger Operation Video Guide

Deleetech SMTD differential pressure meter trigger operation: Place the induction pen at the 3 o'clock position on the SMTD screen, remove the induction pen after the screen flashes, wait for the progress bar to finish flashing, and "E49" will pop up, indicating the trigger is complete.
273 views 0 helpful

SMTD Wireless Remote Differential Pressure Meter - Medium Change Operation Guide

SMTD differential pressure meter medium change procedure: Keep the sensing pen at the 9 o'clock position, remove it once P0 is displayed, then place the sensing pen at the 3 o'clock position to enter the P0 menu, change the medium to argon, repeatedly tap the sensing pen at the 3 o'clock position to switch the medium until argon is displayed, then keep the sensing pen at the 9 o'clock position and wait for the 10-second countdown to complete. Medium change successful.
256 views 0 helpful

SMTD Wireless Remote Differential Pressure Gauge - Diameter Modification Operation Guide

SMTD differential pressure gauge diameter adjustment operation: Place the induction pen at the 9 o'clock position until P0 is displayed, then remove it. Place the induction pen again at the 9 o'clock position until P15 is displayed, then remove it. Place the induction pen at the 3 o'clock position to enter the P15 menu. The current screen shows a diameter of 2110mm, which needs to be changed to 1700mm. Place the induction pen at the 9 o'clock position to switch, then place it at the 3 o'clock position to modify the number. Continue to switch at the 9 o'clock position. Keep the induction pen at the 3 o'clock position and wait until the number 7 is displayed, then remove it. Then place the induction pen at the 9 o'clock position and hold it at the 3 o'clock position to change the thousandth digit to 1, then remove it. Finally, keep the induction pen at the 9 o'clock position to exit, wait for a 10-second countdown to end, and the diameter adjustment is complete.
241 views 0 helpful

SMTD Wireless Remote Differential Pressure Gauge - Volume Modification Operation Guide

SMTD differential pressure gauge volume adjustment operation: Place the sensing pen at the 9 o'clock position, after P0 is displayed, move it away, then place the sensing pen again at the 9 o'clock position, after P10 is displayed, move it away, keep the sensing pen at the 3 o'clock position to enter the P10 menu, the current display shows 20 cubic units, which needs to be changed to 31 cubic units. Place the sensing pen at the 9 o'clock position for the swap operation, after multiple touches to swap, change 0 to 1, then place the sensing pen at the 9 o'clock position to swap, place it at the 3 o'clock position to change 2 to 3, finally keep the sensing pen at the 9 o'clock position to exit, wait for the 10-second countdown to finish, the volume change is successful.
240 views 0 helpful